Professional lighting and effects equipment. Hand made in the USA.
Created 30, April, 1997 |
|
![]()
ABBREVIATED OPERATING INSTRUCTIONS
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER.
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS BREAKER.
POWER MUST BE APPLIED TO AT LEAST CHANNEL # 1 (THE LEFTMOST CONNECTOR) FOR THE FLICKER CONTROL SYSTEM TO OPERATE!
set effect SELECT switches 1 THRU 4 UP
(NO FLICKER), press "ON" button, lamps should light, set "HIGH" KNOBS for HIGHEST LIGHT level. SELECT
EFFECT, SET "LOW" KNOBS FOR LOWEST LIGHT LEVEL. effect will take place between the two SETTINGS. "DELAY"
adjusts speed. GREEN LAMP FLASHES AT 1 HZ IF GROUND IS GOOD & VOLTAGE IS 120. THE 3 MINI JACKS ARE INTERFACE OUT.
FUSES ARE # BLF 20 TYPE.
MAX 150 VOLTS AC ONLY! PROVIDE MAINS CIRCUIT BREAKER. USE ONLY WITH INTERFACE INPUTS ON Magic Gadgets
DIMMERS. TO USE: CONNECT INTERFACE CABLE BETWEEN FLICKER 3D AND DIMMER(S), Press DIMMERS "OFF" button,
SET EFFECT SELECT switches 1 THRU 4 UP (NO FLICKER), press FLICKER 3D'S "ON" button, ADJUST DIMMER LEVEL,
lamp should light, SET EFFECT SELECT SWITCHES AS DESIRED. "DELAY" control adjusts speed.
SWITCH 1 2 3 4 = EFFECT SELECTED
ON ON ON ON = FULL ON (NO FLICKER)
OFF ON ON ON = ON CHASE, R TO L
ON OFF ON ON = ON CHASE, L TO R
ON ON OFF ON = OFF CHASE, R TO L
ON ON ON OFF = OFF CHASE, L TO R
OFF OFF ON ON = ON CHASE, L R L R
OFF ON OFF ON = BLINKING LIGHT
OFF ON ON OFF = LIGHTNING 1
ON OFF OFF ON = LIGHTNING 2
ON OFF ON OFF = TV/FILM LIGHT 1
ON ON OFF OFF = TV/FILM LIGHT 2
OFF OFF OFF ON = TV/FILM LIGHT 3
OFF OFF ON OFF = CANDLELIGHT 1
OFF ON OFF OFF = CANDLELIGHT 2
ON OFF OFF OFF = FIRELIGHT 1
OFF OFF OFF OFF = FIRELIGHT 2
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER. Set effect SELECT switches 1 THRU 4 UP (NO FLICKER), press "ON" button,
lamp should light, set "HIGH" KNOB for HIGHEST LIGHT level. SELECT EFFECT, SET "LOW" KNOB FOR LOWEST LIGHT LEVEL. Effect will take place
between the two SETTINGS. "DELAY" KNOB adjusts speed. GREEN LAMP FLASHES 1 HZ IF GROUND IS GOOD & VOLTAGE IS 120. MINI JACK IS INTERFACE OUT.
FUSE is # BLF 20 TYPE.
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER.
Set effect SELECT switches 1 THRU 4 UP (NO FLICKER), press "ON" button,
lamp should light, set "HIGH" KNOB for HIGHEST LIGHT level. SELECT EFFECT, SET "LOW" KNOB FOR LOWEST LIGHT LEVEL. Effect will take place
between the two SETTINGS. "DELAY" KNOB adjusts speed. GREEN LAMP FLASHES 1 HZ IF GROUND IS GOOD & VOLTAGE IS 120. MINI JACK IS INTERFACE OUT.
CIRCUIT BREAKER ON SIDE.
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER.
Set effect SELECT switches 1 THRU 4 UP (NO FLICKER), press "ON" button,
lamp should light, set "HIGH" KNOB for HIGHEST LIGHT level. SELECT EFFECT, SET "LOW" KNOB FOR LOWEST LIGHT LEVEL. Effect will take place
between the two SETTINGS. "DELAY" KNOB adjusts speed. GREEN LAMP FLASHES 1 HZ IF GROUND IS GOOD & VOLTAGE IS 120. MINI JACK IS INTERFACE OUT.
CIRCUIT BREAKER ON SIDE.
MAX 250 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER.
Set effect SELECT switches 1 THRU 4 UP (NO FLICKER), press "ON" button,
lamp should light, set "HIGH" KNOB for HIGHEST LIGHT level. SELECT EFFECT, SET "LOW" KNOB FOR LOWEST LIGHT LEVEL. Effect will take place
between the two SETTINGS. "DELAY" KNOB adjusts speed. GREEN LAMP FLASHES 1 HZ IF GROUND IS GOOD & VOLTAGE IS 220. MINI JACK IS INTERFACE
OUT. CIRCUIT BREAKER ON SIDE.
SWITCH 1 2 3 4 = EFFECT SELECTED
ON ON ON ON = FULL ON (NO FLICKER)
OFF ON ON ON = TV/FILM LIGHT 1
ON OFF ON ON = TV/FILM LIGHT 2
ON ON OFF ON = TV/FILM LIGHT 3
ON ON ON OFF = TV/FILM LIGHT 4
OFF OFF ON ON = FIRELIGHT 1
OFF ON OFF ON = FIRELIGHT 2
OFF ON ON OFF = FIRELIGHT 3
ON OFF OFF ON = FIRELIGHT 4
ON OFF ON OFF = FIRELIGHT 5
ON ON OFF OFF = FIRELIGHT 6
OFF OFF OFF ON = LIGHTNING 1
OFF OFF ON OFF = LIGHTNING 2
OFF ON OFF OFF = PULSATING LIGHT 1
ON OFF OFF OFF = PULSATING LIGHT 2
OFF OFF OFF OFF = BLINKING LIGHT
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER.
APPLY POWER WITH MODE (TOGGLE) SWITCH IN CENTER (OFF)
POSITION. TURN MODE SWITCH TO DOWN (DIMMER ONLY), set "LOW" limit control to desired level, TURN MODE SWITCH TO UP (FLICKER), SET DELAY (SPEED)
CONTROL TO A MEDIUM RATE. Set "HIGH" limit for desired HIGHEST level. Effect will take place between these two levels. RED LED INDICATOR NEXT TO
MODE SWITCH WILL LIGHT IN BOTH DIMMER AND FLICKER MODES.
RED NEON LAMP INDICATES ACTIVE OUTPUT BUT WILL LIGHT REGARDLESS OF DIAL SETTING IF LOAD
IS DISCONNECTED OR IF LOAD POWER SWITCH IS OFF. GREEN LAMP FLASHES AT 1 HZ IF GROUND IS GOOD & VOLTAGE IS 120. FUSE IS # BLF 20 TYPE.
NOTE: WHEN USING DIMMER ONLY MODE THE HIGH SET CONTROL SHOULD BE TURNED ALL THE WAY DOWN (CCW) TO COMPLETELY EXTINGUISH THE LAMP.
CAUTION: THIS DEVICE CAN OUTPUT IN EXCESS OF 6,000 CANDLEPOWER!
The output device (large silver transistor) can get quite hot. Use care when adjusting the output level as your fingers might find this HOT
object. Some materials may melt if left in contact with this component. be sure nothing touches it during operation. The dimmer control (white
finger twist) will operate the lamp from full off to full on. The switch opposite the LED indicator is the power switch. The switch next to the LED
is the mode (flicker/steady) switch. The LED will light even if the lamp is burned out. When the power is ON the batteries are being used even
when the dimmer knob is turned all the way down and the lamp is extinguished. lamp should be replaced with one no larger than 4 watts.
{FLICKERLANTERN ONLY: To replace lamp, pull up on spring loaded top vent, tip & pull the frosted glass out). Power the unit with a 24 volt DC adapter {supplied with Flickerlantern} or battery power. Any dc power source up to 28 volts {center
pin positive on Flickerlantern} will work. An ideal power source for minimal size is three 9 volt snap connect alkaline batteries in series. Battery life
depends on temperature and battery condition.
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER.
REPLACE MAIN FUSE ONLY WITH BLF 20 AMP AND TRIGGER FUSE
ONLY WITH AGC 6 AMP FAST BLOW TYPE. UNIT RATED 1,800 WATTS MAXIMUM CONSTANT LOAD 2,400 WATTS MAXIMUM INTERMITTENT
LOAD. COMBINED MAIN LOAD AND TRIGGER LOAD MUST NOT EXCEED 20
AMPS! Connect the appliance to be used as the trigger source (I.E PRACTICAL LAMP) to the connector
marked "TRIGGER" on the side. THIS LOAD MUST NOT EXCEED 600
WATTS! When THE APPLIANCE is turned on or off the load connector AS WELL AS THE
INTERFACE CONNECTOR (THE 3.5MM MINI PHONE CONNECTOR) will follow both on AND off DEPENDING ON THE POSITION OF THE TOGGLE SWITCH (IT INVERTS THIS
EFFECT) The "TEST" button can be used to MANUALLY ACTUATE the unit. THE
RED NEON LAMP INDICATES ACTIVE OUTPUT. GROUND/VOLTAGE INDICATOR (GREEN
LAMP) BLINKS AT APPROXIMATELY 1 HZ PER SECOND IF VOLTAGE IS 120 AND GROUND IS SECURE (INTERFACE DISCONNECTED). LIVE LONG AND PROSPER, USE
SECURE GROUNDING.
* TO USE MORE THAN ONE RECEIVER WITH ONE TRANSMITTER, PRESS "CODE" BUTTON UNTIL ADJACENT LED GOES OFF (ERASES ALL CODES) PRESS BUTTON AGAIN
THEN KEY THE TRANSMITTER, NEW CODE IS "LEARNED". UP TO 4 CODES CAN BE HELD IN MEMORY.
* MINI-JACK ON TOP RIGHT IS INTERFACE OUTPUT. IT TOGGLES ON/OFF WITH EACH TRANSMITTER ACTUATION. THIS IS FOR REMOTE SWITCHING OF Magic
Gadgets DIMMERS, ETC.
* KEEP THE RECEIVER AWAY FROM METAL OBJECTS TO MAINTAIN OPTIMUM RANGE. NEVER USE METAL FOIL I.D. LABELS ON OR ENCLOSE THE TRANSMITTER
UNIT IN A METAL ENCLOSURE AS IT WILL "DE-TUNE" THE TRANSMITTER FREQUENCY MAKING OPERATION UNRELIABLE..
IMPORTANT WIRELESS CUE LIGHT INFORMATION
GENERAL OPERATION:
1) DELAY: AS WITH ALL CODED RADIO FREQUENCY TRANSMITTERS IT TAKES A MOMENT FOR THE TRANSMITTED CODE TO BE RECOGNIZED BY THE RECEIVER. YOU MUST HOLD THE BUTTON FOR A MOMENT (COUNT ONE-THOUSAND-ONE) INSTEAD OF PUNCHING IT AS YOU MIGHT A TELEPHONE KEYPAD. THERE IS A SLIGHT DELAY BEFORE THE RECEIVER LAMP WILL LIGHT. THE RED LED WILL LIGHT BEFORE THE LARGE WHITE LAMP. IT IS BEST TO FAMILIARIZE YOURSELF WITH THESE DELAYS PRIOR TO OPERATING THE SYSTEM.
2) CONTROLS: THE 3 POSITION TOGGLE SWITCH OPPOSITE THE &DIM& (DIMMER) KNOB ALLOWS THREE MODES OF LAMP OPERATION: CENTER = LED ONLY, LEFT = LED AND LARGE WHITE LAMP, RIGHT = LED AND LARGE WHITE LAMP FLASHING. IN FLASHING MODE THE LAMP TOGGLES ON AND OFF WITH EACH TRANSMITTER BUTTON PRESS.
3) BRIGHTNESS: THE DIMMER KNOB AFFECTS ONLY THE LARGE WHITE LAMP. THE DIMMER ALLOWS YOU TO USE THE CUE LIGHT NEAR THE CAMERA WITHOUT WASHING LIGHT INTO THE LENS OR ONTO THE SET.
4) POWER SOURCE: IT IS IMPORTANT TO TURN OFF RECEIVER POWER AFTER USE TO CONSERVE BATTERIES. THE TRANSMITTER, HOWEVER, ONLY USES POWER WHEN TRANSMITTING. CONNECT THE AC ADAPTER (OR A SOURCE OF 24 VOLTS DC MAXIMUM!) AT THE LEFT SIDE OF THE UNIT FOR EXTENDED USE. WHEN USING EXTERNAL POWER THE POWER SWITCH IS DISABLED. BATTERIES ARE 3 QUANTITY OF A 9 VOLT SNAP CONNECT TYPE LOCATED IN THE BATTERY COMPARTMENT AT THE BOTTOM OF THE UNIT. USE ONLY ALKALINE BATTERIES FOR BEST PERFORMANCE. DO NOT OVERTIGHTEN THE BATTERY COVER SCREWS AS THIS WILL STRIP THE THREADS.
5) PRESS THE TEST BUTTON ON THE REAR OF THE UNIT TO CHECK THE WHITE LIGHT BULB. WHEN SHIPPED FROM THE FACTORY A SPARE LAMP IS PLACED UNDER THE FOAM RUBBER IN THE BATTERY COMPARTMENT.
USING MULTIPLE UNITS:
1) TRANSMITTERS: ONLY ONE TRANSMITTER CAN BE ACTIVATED AT A TIME. PRESSING MORE THAN ONE TRANSMITTER BUTTON AT ONCE WILL CONFUSE THE RECEIVERS AND NO RECEIVER LAMPS WILL LIGHT.
2) RECEIVERS: TO USE SEVERAL RECEIVERS WITH A SINGLE TRANSMITTER BUTTON, PRESS "CODE" BUTTON ON THE BACK OF THE RECEIVER UNTIL THE GREEN LED GOES OFF, THIS ERASES ALL CODES IN THE RECEIVERS MEMORY. PRESS THE "CODE" BUTTON AGAIN, THE GREEN LED WILL STAY LIT UNTIL A TRANSMITTER BUTTON IS PRESSED (COUNT ONE-THOUSAND-ONE). WHEN THE GREEN LED GOES OFF THE NEW CODE HAS BEEN LEARNED BY THE RECEIVER. UP TO 4 CODES CAN BE HELD IN MEMORY AT THE SAME TIME. THIS MEMORY IS "NONVOLATILE", I.E. THE CODES ARE REMEMBERED EVEN WHEN THE UNIT IS OFF OR WHEN BATTERIES ARE BEING REPLACED.
AUXILIARY OUTPUTS:
1) THE INTERFACE: THE 2 CONDUCTOR MINI-JACK ON THE TOP RIGHT OF THE UNIT IS INTERFACE OUTPUT. IT TOGGLES ON/OFF WITH EACH TRANSMITTER ACTUATION. THIS IS FOR REMOTE SWITCHING OF Magic Gadgets DIMMERS, ETC.
RADIO FREQUENCY SYSTEM:
1) RANGE: THE TRANSMITTING RANGE OF THIS 390 MEGAHERTZ SYSTEM IS EXCELLENT BUT DEPENDS UPON ENVIRONMENTAL CONDITIONS AND BATTERY CONDITION. CHANGE THE LOCATION OF THE TRANSMITTER AND RECEIVER IF RANGE SEEMS LOW. CHECK BATTERIES NEXT. ALSO, KEEP THE RECEIVER AWAY FROM LARGE METALLIC OBJECTS. ATTACH THE ANTENNA TO THE GREEN JACK ON THE TOP OF THE UNIT TO EXTEND RANGE.
2) OBSTACLES: CUTTING THROUGH WOODEN SET WALLS IS USUALLY NO PROBLEM. metallic I.D. LABELS APPLIED TO THE TRANSMITTER CAN block OR de-tunE the radio frequencIES USED. Keep in mind that nonmetallic labels would be best as metallic ones may limit the transmitting range.
COOL TRICKS:
1) AVOID CONFUSION: USE DIFFERENT COLORED GEL OVER THE LAMPS TO COLOR CODE THE LIGHT WHEN YOU HAVE SEVERAL RECEIVERS IN THE SAME AREA AND WANT TO CUE MORE THAN ONE ACTOR SEPARATELY.
2) DAYLIGHT: TO CONCENTRATE THE DIRECTION OF THE LIGHT AND INCREASE CONTRAST, SUCH AS WHEN USING IN BRIGHT LIGHTING CONDITIONS, MAKE A "SNOOT" OUT OF PAPER OR CARD STOCK AROUND THE WHITE LAMP.
3) NON-CUE LIGHT USE: TO ACTUATE EXTERNAL DEVICES OTHER THAN MAGIC GADGETS, CONNECT A REED OR OTHER LOW CURRENT RELAY (12 VOLTS DC AT MAXIMUM 20 MILLIAMPERE LOAD) TO THE INTERFACE MINI-JACK ON THE TOP OF THE UNIT. ANY CONNECTIONS TO THIS JACK MUST BE ISOLATED FROM THE INTERNAL CIRCUITS!
PROVIDE ADEQUATE VENTILATION. HEAT SINKS CAN GET VERY HOT DURING NORMAL OPERATION. USE EXTREME CAUTION IN AUTOMOBILES, ETC AS SOME
MATERIALS MAY MELT IF LEFT IN CONTACT. USE ONLY AGC 10 FAST BLOW TYPE FUSES. INPUT RANGE 3 - 28 VOLTS DC. UNIT RATED 10 AMPS MAXIMUM CONSTANT LOAD 20
AMPS PEAK INTERMITTENT LOAD. WIRING CODE AT TERMINAL BLOCK (USE LUGS CRIMPED TO WIRES): G = GROUND REFERENCE (LIGHT GUAGE WIRE OK IF NOT IN
LOAD CIRCUIT), I = POWER SOURCE POSITIVE INPUT, O = POSITIVE LOAD OUTPUT (BOTH REQUIRE HEAVY GUAGE WIRE SUCH AS # 10 STRANDED. LONG WIRES MAY
REQUIRE HEAVIER WIRE. CONNECT NEGATIVE LOAD (ALSO # 10 WIRE) DIRECTLY TO POWER SOURCE MINUS. RED LED LAMP INDICATES POWER PRESENT AT INPUT.
CONNECTOR ABOVE FUSES IS INTERFACE INPUT. DIMMER IS OFF WHEN INPUT IS HIGH. WHEN USED
with flicker generator THE FLICKER (OR OTHER EFFECT) WILL BE
INVERTED. USE ONLY Magic Gadgets FLICKER & CONTROL DEVICES.
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER. REPLACE FUSE ONLY WITH # BLF 20 AMP FAST BLOW TYPE. UNIT
RATED 2,000 WATTS MAXIMUM CONSTANT LOAD, 2,400 WATTS MAXIMUM INTERMITTENT LOAD. PUSH GREEN BUTTON TO TURN UNIT ON, RED BUTTON TO TURN UNIT OFF
OR TO CONTROL VIA INTERFACE INPUT (MINI JACKS ON SIDE) AS WHEN USED WITH OUR FLICKER GENERATORS AND OTHER EFFECTS DEVICES. SECOND JACK GOES
TO NEXT DIMMER IN DAISY-CHAIN IF MORE THAN ONE DIMMER IS USED. RED LAMP INDICATES ACTIVE OUTPUT BUT WILL LIGHT REGARDLESS OF DIAL SETTING IF
LOAD IS DISCONNECTED OR IF LOAD POWER SWITCH IS OFF. GROUND/VOLTAGE INDICATOR (GREEN LAMP) BLINKS AT APPROXIMATELY 1 HZ PER SECOND IF VOLTAGE
IS 120 AND GROUND IS SECURE (INTERFACE CABLE DISCONNECTED). USE ONLY Magic Gadgets FLICKER & CONTROL DEVICES. LIVE LONG AND PROSPER, USE
SECURE GROUNDING.
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER. DO NOT BLOCK VENTILATION HOLES. RATED 5,000 WATTS
MAXIMUM CONSTANT LOAD 6,000 WATTS MAXIMUM INTERMITTENT LOAD. WIRING CODE: BLACK= HOT, WHITE= NEUTRAL, GREEN= EARTH GROUND. PUSH GREEN BUTTON TO
TURN UNIT ON, RED BUTTON TO TURN UNIT OFF OR TO CONTROL VIA INTERFACE INPUT (MINI JACKS ON SIDE), SECOND JACK GOES TO NEXT DIMMER IN DAISY-CHAIN IF
MORE THAN ONE DIMMER IS USED with flicker
generator. RED LAMP INDICATES ACTIVE OUTPUT BUT WILL LIGHT REGARDLESS OF DIAL SETTING IF LOAD
IS DISCONNECTED OR IF LOAD POWER SWITCH IS OFF. GROUND/VOLTAGE INDICATOR (GREEN LAMP) BLINKS AT APPROXIMATELY 1 HZ PER SECOND IF VOLTAGE IS
120 AND GROUND IS SECURE (INTERFACE CABLE DISCONNECTED). USE ONLY Magic Gadgets FLICKER & CONTROL DEVICES. LIVE LONG AND PROSPER, USE
SECURE GROUNDING.
MAX 150 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER. DO NOT BLOCK VENTILATION HOLES. RATED 10,000 RMS WATTS
MAXIMUM CONSTANT LOAD 12,000 WATTS MAXIMUM INTERMITTENT LOAD! WIRING CODE: BLACK= HOT, WHITE= NEUTRAL, GREEN= EARTH GROUND. PUSH GREEN BUTTON
TO TURN UNIT ON, RED BUTTON TO TURN UNIT OFF OR TO CONTROL VIA INTERFACE INPUT (MINI JACKS ON SIDE), SECOND JACK GOES TO NEXT DIMMER IN
DAISY-CHAIN IF MORE THAN ONE DIMMER IS REQUIRED. ALL DEVICES USING INTERFACE SHOULD BE ON SAME POWER LEG AND SECURELY GROUNDED. CONNECT
INTERFACE BEFORE APPLYING POWER!
RED LAMP INDICATES ACTIVE OUTPUT BUT WILL LIGHT REGARDLESS OF DIAL SETTING IF LOAD IS DISCONNECTED OR IF LOAD POWER SWITCH IS OFF.
GROUND/VOLTAGE INDICATOR (GREEN LAMP) BLINKS AT APPROXIMATELY 1 HZ PER SECOND IF VOLTAGE IS 120 AND GROUND IS SECURE (INTERFACE CABLE
DISCONNECTED). USE ONLY Magic Gadgets FLICKER & CONTROL DEVICES. LIVE LONG AND PROSPER, USE SECURE GROUNDING.
MAX 250 VOLT AC ONLY! PROVIDE ADEQUATE VENTILATION AND MAINS CIRCUIT BREAKER. DO NOT BLOCK VENTILATION HOLES. RATED 24,000 WATTS
MAXIMUM CONSTANT LOAD 22,000 WATTS MAXIMUM INTERMITTENT LOAD! WIRING CODE: BLACK= HOT, WHITE= NEUTRAL, GREEN= EARTH GROUND. PUSH GREEN BUTTON
TO TURN UNIT ON, RED BUTTON TO TURN UNIT OFF OR TO CONTROL VIA INTERFACE INPUT (MINI JACKS ON SIDE), SECOND JACK GOES TO NEXT DIMMER IN
DAISY-CHAIN IF MORE THAN ONE DIMMER IS REQUIRED. ALL DEVICES USING INTERFACE SHOULD BE ON SAME POWER LEG AND SECURELY GROUNDED. CONNECT
INTERFACE BEFORE APPLYING POWER!
RED LAMP INDICATES ACTIVE OUTPUT BUT WILL LIGHT REGARDLESS OF DIAL SETTING IF LOAD IS DISCONNECTED OR IF LOAD POWER SWITCH IS OFF.
GROUND/VOLTAGE INDICATOR (GREEN LAMP) BLINKS AT APPROXIMATELY 1 HZ PER SECOND IF VOLTAGE IS 220 AND GROUND IS SECURE (INTERFACE CABLE
DISCONNECTED). USE ONLY Magic Gadgets FLICKER & CONTROL DEVICES. LIVE LONG AND PROSPER, USE SECURE GROUNDING.
|